Order No. | Name | Model | D65 | TL84 | F | UV | CWF | TL83 | Voltage |
10113 | Standard light source booth | P60(6) six light source(220V) | 2pcs | 2pcs | 4pcs | 1pcs | 2pcs | 2pcs | 220V/50Hz |
10813 | Standard light source booth | P60(6) six light source(115V) | 2pcs | 2pcs | 4pcs | 1pcs | 2pcs | 2pcs | 115V/60Hz |
Optional accessories: light source diffuser 45 degree standard stand.
Light Source | Color viewing booths application | Color temperature(k) | Power(W) |
D65 | International standard Artificial Daylight | 6500 | 18 |
TL84 | Applied to stores in Europe, Japan and China | 4000 | 18 |
CWF | (Cool White Fluorescent) American Standard | 4150 | 18 |
F/A | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
UV |
Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments |
Wave length:365nm | 20 |
TL83 | Warm White Fluorescent American Standard | 3000 | 18 |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
SCI&SCE are two method in the color measurement. SCI means Specular Component Include,SCE means Specular Component Exclude.
Under the method of SCE, only test diffuse refection and exclude specular reflection. In that way, the test result is similar to object color was observed by human eyes.
Under the method SCI, both the diffuse refection and specular reflection will be included. In that way, the value about the color is more objective. It will not effect by the environment condition.
When we choose the instrument, those elements should be taking into consideration.
Threenh Technology colorimeters provide a color deviation prompt function according to the Lab value, which can provide a reference for color matching. The handheld colorimeter can only indicate blacker, whiter, redder, greener, yellower or bluer, but it cannot provide accurate color formulas. Only with the help of a spectrophotometer and professional color matching software can fully realized automated color matching.
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.
To answer this question, you first need to clarify your specific needs:
Is it for simple color quality control (QC)?
To coordinate with supply chain color management?
To monitor on-line color stability?
Do you require computer color matching or production color correction?
What is your budget?
Systematic supervision and evaluation of color performance in dyed products?
If you aren’t fully clear about your requirements at the initial stage, our color management engineers are ready to communicate with you. We will recommend solutions tailored to your needs. When conditions permit, we can provide prototype demonstrations and trial testing to ensure the instrument meets your practical application requirements.