Spectrodensitometer YD5050

In line with Chinese Grade 1 Spectrodensitometer standard

3nh YD5050 Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control


Key Highlights

  • 45/0 geometrical optics structure, comply with CIE

  • Reflectance spectrum, CMYK density and Lab

  • 3.5-inch TFT true-color screen, capacitive touch screen, concave grating

  • Ergonomic structure design

  • Φ2/4/8mm Optional apertures

  • Pinting plants process control and quality control

This YD5050 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

3nh launched new model YD5050 Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard  ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing.
 

Under the 45/0 geometric optical illumination and the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, the instrument can accurately measure the reflectance data of samples. Under multiple color spaces, it can accurately measure various printing density indexes, color difference formulas and color indexes, and can meet the user's regular testing of various parameters.
 

Product Features
 

1. 45/0 geometrical optics structure, comply with CIE, the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, it can accurately measure various printing density , overprint rate and other printing parameters.

2. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample;

3. High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.;

4. Perfect combination of the beautiful appearance and the ergonomic structure design;

5. Optional apertures: Φ2/4/8mm, adapt to more samples;

6. Large-capacity storage space, over 20,000 test data

7. Combined LED light sources with long life and low power consumption, including UV light;

8.  USB/Blue2.1 dual communication mode is widely useful;

9. Especially suitable for process control and quality control of printing plants;

10. PC software has powerful function expansion.

 

ModelYD5050
Measurement Geometry 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15
Features high accuracy spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm.
Light Source Combined LED Light, UV Light
Spectral separation device Concave Grating
Detector 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 400~700nm
Wavelength Pitch 10nm
Half Bandwidth 10nm
Measurement Conditions Compliance with ISO 13655 measurement conditions;
M0 (CIE Light Soure A)
M1 (CIE Light Soure D50)
M2 (Excluding UV light source)
M3 (M2+Polarized light filter)
Density Standards ISO Status A, E, I, T
Density index Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray scale, density scanning
Measurement aperture Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional
Color Spaces CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB
Color Difference Formula ΔE*ab,ΔE*94,ΔE*00,ΔE*uv,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE(Hunter)
Other Colorimetric Index WI(ASTM E313,CIE/ISO,AATCC,Hunter),
YI(ASTM D1925,ASTM 313),
MI (Metamerism Index),Opacity,
Observer Angle 2°/10°
Illuminants A,C,D50,D55,D65,D75, F2(CWF),F7(DLP), F11(TL84),F12(TL83/U30), F1,F3,F4,F5,F6,F8,F9,F10(TPL5)
Measurement Time About 1.5s
Repeatability Density: Within 0.01 D
Chromaticity value:within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)  Except M3
Inter-instrument Error Within ΔE*ab 0.18 (Average for 12 BCRA Series II color tiles) Except M3
Measurement mode Single Measurement, Average Measurement(2-99)
Size(L*W*H) 184*77*105mm
Weight About 600g
Power source Li-ion battery. 5000 measurements within 8 hours
Illuminant Life Span 5 years, more than 3 million times measurements
Display 3.5-inch TFT color LCD, Capacitive Touch Screen
Interface USB, Bluetooth ®5.0
Data memory 20000 pcs
Language
Simplified Chinese, English, Traditional Chinese
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation);altitude: less than 2000 m
Storage Environment  Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate
Optional Accessory Micro Printer
Notes: The specifications are subject to change without notice.


12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

Our Valued Clients

FAQs About Spectrodensitometer

Opaque liquids and powders can be put into a cuvette for color measurement. 

After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.

Yes, we can offer quality certification issued by our lab free of charge, or issued by third-party international inspection Organizations with extra charge, please contact us for confirmation.

D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries. 

Threenh Technology with excellent after sale service, Generally, Our warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept. lf you have any technical problem or question with our goods welcome to contact us.

Related Spectrodensitometer You May Also Like